1 CVE-2014-8552 200 +Info 2014-11-26 2014-11-26
5.0
None Remote Low Not required Partial None None
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
2 CVE-2014-8551 94 Exec Code 2014-11-26 2014-11-26
10.0
None Remote Low Not required Complete Complete Complete
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.
3 CVE-2014-4686 +Info 2014-07-24 2014-07-25
6.8
None Remote Medium Not required Partial Partial Partial
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.
4 CVE-2014-4685 264 +Priv 2014-07-24 2014-07-25
4.6
None Local Low Not required Partial Partial Partial
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
5 CVE-2014-4684 264 +Priv 2014-07-24 2014-07-25
6.0
None Remote Medium ??? Partial Partial Partial
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.
6 CVE-2014-4683 264 +Priv 2014-07-24 2014-07-25
4.9
None Remote Medium ??? Partial Partial None
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
7 CVE-2014-4682 200 +Info 2014-07-24 2014-07-25
5.0
None Remote Low Not required Partial None None
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.
8 CVE-2014-2733 20 DoS 2014-04-19 2014-04-21
5.0
None Remote Low Not required None None Partial
Siemens SINEMA Server before 12 SP1 allows remote attackers to cause a denial of service (web-interface outage) via crafted HTTP requests to port (1) 4999 or (2) 80.
9 CVE-2014-2732 22 Dir. Trav. 2014-04-19 2015-10-08
5.0
None Remote Low Not required Partial None None
Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80.
10 CVE-2014-2731 Exec Code 2014-04-19 2014-04-21
9.3
None Remote Medium Not required Complete Complete Complete
Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to execute arbitrary code via HTTP traffic to port (1) 4999 or (2) 80.
11 CVE-2014-2590 20 DoS 2014-04-01 2014-04-01
5.0
None Remote Low Not required None None Partial
The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets.
12 CVE-2014-2259 DoS 2014-03-16 2020-02-10
7.8
None Remote Low Not required None None Complete
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets.
13 CVE-2014-2257 DoS 2014-03-16 2020-02-10
7.8
None Remote Low Not required None None Complete
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets.
14 CVE-2014-2255 DoS 2014-03-16 2020-02-10
7.8
None Remote Low Not required None None Complete
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets.
15 CVE-2014-2253 DoS 2014-03-16 2020-02-10
6.1
None Local Network Low Not required None None Complete
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets.
16 CVE-2014-2251 2014-03-16 2020-02-10
8.3
None Remote Medium Not required Partial Partial Complete
The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors.
17 CVE-2014-2249 352 CSRF 2014-03-16 2014-03-26
5.8
None Remote Medium Not required None Partial Partial
Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
18 CVE-2014-2248 2014-03-16 2020-02-10
4.3
None Remote Medium Not required None Partial None
Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.
19 CVE-2014-2247 2014-03-16 2020-02-10
5.8
None Remote Medium Not required None Partial Partial
The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors.
20 CVE-2014-2246 79 XSS 2014-03-16 2020-02-10
4.3
None Remote Medium Not required None Partial None
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
21 CVE-2014-1966 399 DoS 2014-02-24 2014-02-24
7.8
None Remote Low Not required None None Complete
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets.
22 CVE-2014-1699 399 DoS 2014-02-07 2017-08-29
5.0
None Remote Low Not required None None Partial
Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999.
23 CVE-2014-1698 22 Dir. Trav. 2014-02-07 2017-08-29
5.0
None Remote Low Not required Partial None None
Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999.
24 CVE-2014-1697 Exec Code 2014-02-07 2017-08-29
7.5
None Remote Low Not required Partial Partial Partial
The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999.
25 CVE-2014-1696 310 2014-02-07 2017-08-29
5.0
None Remote Low Not required Partial None None
Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack.
26 CVE-2014-0160 119 2 Overflow +Info 2014-04-07 2020-07-28
5.0
None Remote Low Not required Partial None None
The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug.
Total number of vulnerabilities : 26   Page : 1 (This Page)
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.