CVE ID
|
CWE ID
|
# of Exploits
|
Vulnerability Type(s)
|
Publish Date
|
Update Date
|
Score
|
Gained Access Level
|
Access
|
Complexity
|
Authentication
|
Conf.
|
Integ.
|
Avail.
|
1 |
CVE-2015-2823 |
287 |
|
|
2015-04-08 |
2016-11-28 |
6.8 |
None |
Remote |
Medium |
Not required |
Partial |
Partial |
Partial |
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password. |
2 |
CVE-2014-4686 |
|
|
+Info |
2014-07-24 |
2014-07-25 |
6.8 |
None |
Remote |
Medium |
Not required |
Partial |
Partial |
Partial |
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. |
3 |
CVE-2014-4685 |
264 |
|
+Priv |
2014-07-24 |
2014-07-25 |
4.6 |
None |
Local |
Low |
Not required |
Partial |
Partial |
Partial |
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. |
4 |
CVE-2014-4684 |
264 |
|
+Priv |
2014-07-24 |
2014-07-25 |
6.0 |
None |
Remote |
Medium |
??? |
Partial |
Partial |
Partial |
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433. |
5 |
CVE-2014-4683 |
264 |
|
+Priv |
2014-07-24 |
2014-07-25 |
4.9 |
None |
Remote |
Medium |
??? |
Partial |
Partial |
None |
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. |
6 |
CVE-2014-4682 |
200 |
|
+Info |
2014-07-24 |
2014-07-25 |
5.0 |
None |
Remote |
Low |
Not required |
Partial |
None |
None |
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request. |
7 |
CVE-2013-3959 |
200 |
|
+Info |
2013-06-14 |
2013-06-17 |
4.0 |
None |
Remote |
Low |
??? |
Partial |
None |
None |
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. |
8 |
CVE-2013-3958 |
255 |
|
|
2013-06-14 |
2013-06-17 |
7.5 |
None |
Remote |
Low |
Not required |
Partial |
Partial |
Partial |
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. |
9 |
CVE-2013-3957 |
89 |
|
Exec Code Sql |
2013-06-14 |
2013-06-17 |
7.5 |
None |
Remote |
Low |
Not required |
Partial |
Partial |
Partial |
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. |
10 |
CVE-2013-0679 |
22 |
|
Dir. Trav. |
2013-03-21 |
2013-03-22 |
4.0 |
None |
Remote |
Low |
??? |
Partial |
None |
None |
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname. |
11 |
CVE-2013-0678 |
255 |
|
+Info |
2013-03-21 |
2013-03-22 |
4.0 |
None |
Remote |
Low |
??? |
Partial |
None |
None |
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query. |
12 |
CVE-2013-0677 |
200 |
|
DoS +Info |
2013-03-21 |
2013-03-22 |
5.8 |
None |
Remote |
Medium |
Not required |
Partial |
None |
Partial |
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file. |
13 |
CVE-2013-0676 |
264 |
|
+Info |
2013-03-21 |
2013-03-22 |
4.0 |
None |
Remote |
Low |
??? |
Partial |
None |
None |
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query. |
14 |
CVE-2013-0675 |
119 |
|
DoS Overflow |
2013-03-21 |
2013-03-22 |
6.1 |
None |
Local Network |
Low |
Not required |
None |
None |
Complete |
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet. |
15 |
CVE-2013-0674 |
119 |
|
Exec Code Overflow |
2013-03-21 |
2013-03-22 |
6.8 |
None |
Remote |
Medium |
Not required |
Partial |
Partial |
Partial |
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter. |
16 |
CVE-2012-3034 |
200 |
|
+Info |
2012-09-18 |
2012-09-19 |
4.3 |
None |
Remote |
Medium |
Not required |
Partial |
None |
None |
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls. |
17 |
CVE-2012-3032 |
89 |
|
Exec Code Sql |
2012-09-18 |
2012-09-19 |
7.5 |
None |
Remote |
Low |
Not required |
Partial |
Partial |
Partial |
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message. |
18 |
CVE-2012-3031 |
79 |
|
XSS |
2012-09-18 |
2012-09-19 |
4.3 |
None |
Remote |
Medium |
Not required |
None |
Partial |
None |
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header. |
19 |
CVE-2012-3030 |
264 |
|
|
2012-09-18 |
2012-12-20 |
5.0 |
None |
Remote |
Low |
Not required |
Partial |
None |
None |
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. |
20 |
CVE-2012-3028 |
352 |
|
DoS CSRF |
2012-09-18 |
2012-09-19 |
6.8 |
None |
Remote |
Medium |
Not required |
Partial |
Partial |
Partial |
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service. |