Cpe Name: cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*
# |
CVE ID
|
CWE ID
|
# of Exploits
|
Vulnerability Type(s)
|
Publish Date
|
Update Date
|
Score
|
Gained Access Level
|
Access
|
Complexity
|
Authentication
|
Conf.
|
Integ.
|
Avail.
|
1 |
CVE-2011-4879 |
20 |
1
|
DoS |
2012-02-03 |
2017-08-29 |
8.5 |
None |
Remote |
Low |
Not required |
Partial |
None |
Complete |
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. |
2 |
CVE-2011-4878 |
22 |
1
|
Dir. Trav. |
2012-02-03 |
2017-08-29 |
7.8 |
None |
Remote |
Low |
Not required |
Complete |
None |
None |
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. |
3 |
CVE-2011-4877 |
20 |
1
|
DoS |
2012-02-03 |
2017-08-29 |
7.1 |
None |
Remote |
Medium |
Not required |
None |
None |
Complete |
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. |
4 |
CVE-2011-4876 |
22 |
1
|
Dir. Trav. |
2012-02-03 |
2017-08-29 |
9.3 |
None |
Remote |
Medium |
Not required |
Complete |
Complete |
Complete |
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. |
5 |
CVE-2011-4875 |
119 |
1
|
Exec Code Overflow |
2012-02-03 |
2017-08-29 |
9.3 |
None |
Remote |
Medium |
Not required |
Complete |
Complete |
Complete |
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings. |
6 |
CVE-2011-4514 |
287 |
|
|
2012-02-03 |
2012-02-06 |
10.0 |
None |
Remote |
Low |
Not required |
Complete |
Complete |
Complete |
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. |
7 |
CVE-2011-4513 |
|
|
Exec Code |
2012-02-03 |
2012-02-06 |
10.0 |
None |
Remote |
Low |
Not required |
Complete |
Complete |
Complete |
Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader. |
8 |
CVE-2011-4512 |
94 |
|
Http R.Spl. |
2012-02-03 |
2012-02-06 |
5.0 |
None |
Remote |
Low |
Not required |
None |
Partial |
None |
CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors. |
9 |
CVE-2011-4511 |
79 |
|
XSS |
2012-02-03 |
2012-02-06 |
4.3 |
None |
Remote |
Medium |
Not required |
None |
Partial |
None |
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. |
10 |
CVE-2011-4510 |
79 |
|
XSS |
2012-02-03 |
2012-02-06 |
4.3 |
None |
Remote |
Medium |
Not required |
None |
Partial |
None |
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. |
11 |
CVE-2011-4509 |
264 |
|
|
2012-02-03 |
2012-02-06 |
10.0 |
None |
Remote |
Low |
Not required |
Complete |
Complete |
Complete |
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests. |
12 |
CVE-2011-4508 |
287 |
|
Bypass |
2012-02-03 |
2012-02-07 |
9.3 |
None |
Remote |
Medium |
Not required |
Complete |
Complete |
Complete |
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. |
Total number of vulnerabilities : 12
Page :
1
(This Page)
|
|