CVEdetails.com the ultimate security vulnerability data source
(e.g.: CVE-2009-1234 or 2010-1234 or 20101234)
Log In   Register
  What's the CVSS score of your company?
Vulnerability Feeds & WidgetsNew   www.itsecdb.com  

Siemens : Security Vulnerabilities (Denial Of Service)

Press ESC to close
# CVE ID CWE ID # of Exploits Vulnerability Type(s) Publish Date Update Date Score Gained Access Level Access Complexity Authentication Conf. Integ. Avail.
1 CVE-2021-34333 415 DoS 2021-07-13 2021-07-15
4.3
None Remote Medium Not required None None Partial
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in double free of an allocated buffer that leads to a crash. An attacker could leverage this vulnerability to cause denial of service condition. (CNVD-C-2021-79295)
2 CVE-2021-34332 835 DoS 2021-07-13 2021-07-15
4.3
None Remote Medium Not required None None Partial
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to denial of service condition. An attacker could leverage this vulnerability to consume excessive resources. (CNVD-C-2021-79300)
3 CVE-2021-32938 125 DoS 2021-06-17 2021-09-21
5.8
None Remote Medium Not required Partial None Partial
Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.
4 CVE-2021-25178 787 DoS Exec Code Overflow 2021-01-18 2021-03-04
6.8
None Remote Medium Not required Partial Partial Partial
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. This can allow attackers to cause a crash potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution.
5 CVE-2021-25177 843 DoS 2021-01-18 2021-03-02
6.8
None Remote Medium Not required Partial Partial Partial
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart).
6 CVE-2021-25176 476 DoS 2021-01-18 2021-03-04
6.8
None Remote Medium Not required Partial Partial Partial
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart).
7 CVE-2021-25175 704 DoS 2021-01-18 2021-03-04
6.8
None Remote Medium Not required Partial Partial Partial
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Conversion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart).
8 CVE-2021-25174 400 DoS Mem. Corr. 2021-01-18 2021-03-04
6.8
None Remote Medium Not required Partial Partial Partial
An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It can allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart).
9 CVE-2021-25173 770 DoS 2021-01-18 2021-03-16
6.8
None Remote Medium Not required Partial Partial Partial
An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory allocation with excessive size vulnerability exists when reading malformed DGN files, which allows attackers to cause a crash, potentially enabling denial of service (crash, exit, or restart).
10 CVE-2021-3449 476 DoS 2021-03-25 2021-10-20
4.3
None Remote Medium Not required None None Partial
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
11 CVE-2019-19300 400 DoS 2020-04-14 2021-03-15
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), KTK ATE530S (All versions), SIDOOR ATD430W (All versions), SIDOOR ATE530S COATED (All versions), SIDOOR ATE531S (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 MF HF (All versions), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC MICRO-DRIVE PDC (All versions), SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) (All versions >= V4.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINAMICS S/G Control Unit w. PROFINET (All versions). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
12 CVE-2019-13946 400 DoS 2020-02-11 2021-10-12
7.8
None Remote Low Not required None None Complete
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, PROFINET Driver for Controller, RUGGEDCOM RM1224, SCALANCE M-800, SCALANCE S615, SCALANCE W700 IEEE 802.11n, SCALANCE X-200 switch family (incl. SIPLUS NET variants), SCALANCE X-200IRT (incl. SIPLUS NET variants), SCALANCE X-300 (incl. X408 and SIPLUS NET variants), SCALANCE XB-200, SCALANCE XC-200, SCALANCE XF-200BA, SCALANCE XM-400, SCALANCE XP-200, SCALANCE XR-300WG, SCALANCE XR-500, SIMATIC CP 1616 and CP 1604, SIMATIC CP 343-1 (incl. SIPLUS variants), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants), SIMATIC CP 343-1 ERPC, SIMATIC CP 343-1 Lean (incl. SIPLUS variants), SIMATIC CP 443-1 (incl. SIPLUS variants), SIMATIC CP 443-1 Advanced (incl. SIPLUS variants), SIMATIC CP 443-1 OPC UA, SIMATIC ET200AL IM 157-1 PN, SIMATIC ET200M IM153-4 PN IO HF (incl. SIPLUS variants), SIMATIC ET200M IM153-4 PN IO ST (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN Basic (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0), SIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0), SIMATIC ET200pro, IM 154-3 PN HF, SIMATIC ET200pro, IM 154-4 PN HF, SIMATIC IPC Support, Package for VxWorks, SIMATIC MV400, SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant), SIMATIC RF180C, SIMATIC RF182C, SIMATIC RF600, SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION P, SINAMICS DCP, SOFTNET-IE PNIO. Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
13 CVE-2019-10931 DoS 2019-07-11 2021-10-28
5.0
None Remote Low Not required None None Partial
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
14 CVE-2019-8276 787 DoS Overflow 2019-03-08 2020-10-22
5.0
None Remote Low Not required None None Partial
UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
15 CVE-2019-8269 787 DoS Overflow 2019-03-08 2020-10-19
5.0
None Remote Low Not required None None Partial
UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207.
16 CVE-2019-8263 787 DoS Overflow 2019-03-05 2021-06-28
4.3
None Remote Medium Not required None None Partial
UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.
17 CVE-2016-9157 20 DoS Exec Code 2016-12-05 2017-06-13
7.5
None Remote Low Not required Partial Partial Partial
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to cause a Denial of Service condition and potentially lead to unauthenticated remote code execution by sending specially crafted packets to port 19234/TCP.
18 CVE-2016-8563 20 DoS 2016-10-13 2017-07-29
5.0
None Remote Low Not required None None Partial
Siemens Automation License Manager (ALM) before 5.3 SP3 Update 1 allows remote attackers to cause a denial of service (ALM service outage) via crafted packets to TCP port 4410.
19 CVE-2016-5874 20 DoS 2016-07-22 2016-11-28
5.0
None Remote Low Not required None None Partial
Siemens SIMATIC NET PC-Software before 13 SP2 allows remote attackers to cause a denial of service (OPC UA service outage) via crafted TCP packets.
20 CVE-2016-3963 DoS 2016-04-08 2018-05-26
5.0
None Remote Low Not required None None Partial
Siemens SCALANCE S613 allows remote attackers to cause a denial of service (web-server outage) via traffic to TCP port 443.
21 CVE-2015-2822 20 DoS 2015-04-08 2016-11-28
4.3
None Remote Medium Not required None None Partial
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102.
22 CVE-2014-2733 20 DoS 2014-04-19 2014-04-21
5.0
None Remote Low Not required None None Partial
Siemens SINEMA Server before 12 SP1 allows remote attackers to cause a denial of service (web-interface outage) via crafted HTTP requests to port (1) 4999 or (2) 80.
23 CVE-2014-2590 20 DoS 2014-04-01 2014-04-01
5.0
None Remote Low Not required None None Partial
The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets.
24 CVE-2014-2259 DoS 2014-03-16 2020-02-10
7.8
None Remote Low Not required None None Complete
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets.
25 CVE-2014-2257 DoS 2014-03-16 2020-02-10
7.8
None Remote Low Not required None None Complete
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets.
26 CVE-2014-2255 DoS 2014-03-16 2020-02-10
7.8
None Remote Low Not required None None Complete
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets.
27 CVE-2014-2253 DoS 2014-03-16 2020-02-10
6.1
None Local Network Low Not required None None Complete
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets.
28 CVE-2014-1966 399 DoS 2014-02-24 2014-02-24
7.8
None Remote Low Not required None None Complete
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets.
29 CVE-2014-1699 399 DoS 2014-02-07 2017-08-29
5.0
None Remote Low Not required None None Partial
Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999.
30 CVE-2013-2780 119 DoS Overflow 2013-04-22 2020-02-10
7.8
None Remote Low Not required None None Complete
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
31 CVE-2013-0700 119 DoS Overflow 2013-04-22 2020-02-10
7.8
None Remote Low Not required None None Complete
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
32 CVE-2013-0677 200 DoS +Info 2013-03-21 2013-03-22
5.8
None Remote Medium Not required Partial None Partial
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
33 CVE-2013-0675 119 DoS Overflow 2013-03-21 2013-03-22
6.1
None Local Network Low Not required None None Complete
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.
34 CVE-2013-0669 20 DoS 2013-03-21 2013-03-22
4.0
None Remote Low ??? None None Partial
The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request.
35 CVE-2012-4691 399 DoS 2012-12-18 2013-01-29
3.3
None Local Network Low Not required None None Partial
Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets.
36 CVE-2012-3028 352 DoS CSRF 2012-09-18 2012-09-19
6.8
None Remote Medium Not required Partial Partial Partial
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
37 CVE-2012-2598 119 DoS Overflow 2012-06-08 2012-06-12
4.3
None Remote Medium Not required None None Partial
Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.
38 CVE-2011-4879 20 1 DoS 2012-02-03 2017-08-29
8.5
None Remote Low Not required Partial None Complete
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
39 CVE-2011-4877 20 1 DoS 2012-02-03 2017-08-29
7.1
None Remote Medium Not required None None Complete
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.
40 CVE-2011-4531 20 DoS 2012-01-08 2012-01-09
5.0
None Remote Low Not required None None Partial
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
41 CVE-2011-4530 20 DoS 2012-01-08 2012-01-09
5.0
None Remote Low Not required None None Partial
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1) open_session->workstation->NAME or (2) grant->VERSION function.
42 CVE-2011-3321 119 DoS Exec Code Overflow Mem. Corr. 2011-09-16 2017-08-29
9.3
None Remote Medium Not required Complete Complete Complete
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
43 CVE-2009-3322 1 DoS 2009-09-23 2018-10-10
7.8
None Remote Low Not required None None Complete
The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723.
44 CVE-2009-1152 DoS 2009-03-26 2017-09-29
7.3
None Local Network Medium Not required None Complete Complete
Siemens Gigaset SE461 WiMAX router 1.5-BL024.9.6401, and possibly other versions, allows remote attackers to cause a denial of service (device restart and loss of configuration) by connecting to TCP port 53, then closing the connection.
45 CVE-2008-7065 DoS 2009-08-25 2018-10-11
7.8
None Remote Low Not required None None Complete
Siemens C450 IP and C475 IP VoIP devices allow remote attackers to cause a denial of service (disconnected calls and device reboot) via a crafted SIP packet to UDP port 5060.
46 CVE-2008-1267 189 DoS 2008-03-10 2018-10-11
7.8
None Remote Low Not required None None Complete
The Siemens SpeedStream 6520 router allows remote attackers to cause a denial of service (web interface crash) via an HTTP request to basehelp_English.htm with a large integer in the Content-Length field.
47 CVE-2007-4488 DoS XSS 2007-08-22 2018-10-15
4.3
None Remote Medium Not required None Partial None
Multiple cross-site scripting (XSS) vulnerabilities in the Siemens Gigaset SE361 WLAN router with firmware 1.00.0 allow remote attackers to inject arbitrary web script or HTML via the portion of the URI immediately following the filename for (1) a GIF filename, which triggers display of the GIF file in text format and an unspecified denial of service (crash); or (2) the login.tri filename, which triggers a continuous loop of the browser attempting to visit the login page.
48 CVE-2006-3907 DoS 2006-07-27 2018-10-17
5.0
None Remote Low Not required None None Partial
Siemens SpeedStream 2624 allows remote attackers to cause a denial of service (device hang) by sending a crafted packet to the web administrative interface.
49 CVE-2003-1464 119 DoS Overflow 2003-12-31 2017-07-29
7.8
None Remote Low Not required None None Complete
Buffer overflow in Siemens 45 series mobile phones allows remote attackers to cause a denial of service (disconnect and unavailable inbox) via a Short Message Service (SMS) message with a long image name.
50 CVE-2002-0122 DoS 2002-03-25 2008-09-11
5.0
None Remote Low Not required None None Partial
Siemens 3568i WAP mobile phones allows remote attackers to cause a denial of service (crash) via an SMS message containing unusual characters.
Total number of vulnerabilities : 52   Page : 1 (This Page)2
CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site. OVAL is a registered trademark of The MITRE Corporation and the authoritative source of OVAL content is MITRE's OVAL web site.
Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.