CVE ID
|
CWE ID
|
# of Exploits
|
Vulnerability Type(s)
|
Publish Date
|
Update Date
|
Score
|
Gained Access Level
|
Access
|
Complexity
|
Authentication
|
Conf.
|
Integ.
|
Avail.
|
1 |
CVE-2022-29186 |
321 |
|
|
2022-05-20 |
2022-05-20 |
0.0 |
None |
??? |
??? |
??? |
??? |
??? |
??? |
Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files. |
2 |
CVE-2022-0664 |
321 |
|
|
2022-02-18 |
2022-02-26 |
10.0 |
None |
Remote |
Low |
Not required |
Complete |
Complete |
Complete |
Use of Hard-coded Cryptographic Key in Go github.com/gravitl/netmaker prior to 0.8.5,0.9.4,0.10.0,0.10.1. |
3 |
CVE-2021-43587 |
321 |
|
+Priv |
2021-12-21 |
2022-01-05 |
7.2 |
None |
Local |
Low |
Not required |
Complete |
Complete |
Complete |
Dell PowerPath Management Appliance, versions 3.2, 3.1, 3.0 P01, 3.0, and 2.6, use hard-coded cryptographic key. A local high-privileged malicious user may potentially exploit this vulnerability to gain access to secrets and elevate to gain higher privileges. |
4 |
CVE-2021-43552 |
321 |
|
|
2021-12-27 |
2022-01-12 |
2.1 |
None |
Local |
Low |
Not required |
Partial |
None |
None |
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03. |
5 |
CVE-2021-38461 |
321 |
|
|
2021-10-22 |
2021-10-27 |
6.4 |
None |
Remote |
Low |
Not required |
Partial |
Partial |
None |
The affected product uses a hard-coded blowfish key for encryption/decryption processes. The key can be easily extracted from binaries. |
6 |
CVE-2021-32520 |
321 |
|
|
2021-07-07 |
2021-09-21 |
7.5 |
None |
Remote |
Low |
Not required |
Partial |
Partial |
Partial |
Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users’ credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document. |
7 |
CVE-2021-27389 |
321 |
|
|
2021-04-22 |
2021-04-30 |
7.5 |
None |
Remote |
Low |
Not required |
Partial |
Partial |
Partial |
A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection. |
8 |
CVE-2020-28395 |
321 |
|
|
2021-01-12 |
2021-03-26 |
4.3 |
None |
Remote |
Medium |
Not required |
Partial |
None |
None |
A vulnerability has been identified in SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. |
9 |
CVE-2020-28391 |
321 |
|
|
2021-01-12 |
2021-09-14 |
4.3 |
None |
Remote |
Medium |
Not required |
Partial |
None |
None |
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. |
10 |
CVE-2020-25234 |
321 |
|
|
2020-12-14 |
2020-12-16 |
3.6 |
None |
Local |
Low |
Not required |
Partial |
Partial |
None |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions (UDF) in a password protected way. This protection is implemented in the software that displays the information. An attacker could reverse engineer the UDFs directly from stored program files. |
11 |
CVE-2020-25233 |
321 |
|
|
2020-12-14 |
2020-12-16 |
2.1 |
None |
Local |
Low |
Not required |
Partial |
None |
None |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device. |
12 |
CVE-2020-25231 |
321 |
|
|
2020-12-14 |
2020-12-16 |
2.1 |
None |
Local |
Low |
Not required |
Partial |
None |
None |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program files. |
13 |
CVE-2019-10920 |
321 |
|
|
2019-05-14 |
2022-01-04 |
5.0 |
None |
Remote |
Low |
Not required |
Partial |
None |
None |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. |